The paper discussed the design of low cost inverter using SG3525A IC and IRF3205 MOSFET in H-Bridge configuration. The implementation of the real construction involved the use of IC SG3525A for generation of output pulses; the totem pole arrangement of transistors was used in the driver section of the inverter to boost signals as well as switching purposes. The H-bridge configuration was employed to effectively switch the four MOSFETs, this switching produced an alternating potential of 220V. Pre-set conditions such as load condition, low battery cut, overcharge cut and constant output were set at 1700W, 10V, 13.3V and 220V respectively so as to ensure effective and long lasting usage of the inverter. The battery used for the operation of the inverter was 12V maintenance free battery in order to reduce the cost of using the inverter. The various tests carried out on this inverter were tests on inductive loads, resistive loads, home appliances, overload condition, low battery and charging control. The aim of this work is to achieve inverter design analysis under resistive loads and inductive loads for efficient power usage at lowest possible cost. This was achieved by connecting various resistive and inductive loads on the inverter. The results show that the system can operate under both the resistive and inductive loads but operates better under resistive loads, the reason for this is that inductive loads always draw large currents during start-ups which always result to power losses.

Graphs were plotted and analyzed; the results also showed that this inverter can take up to 1700W of resistive load and inductive load of 1020W. The inverter produced no humming sound from inductive loads and home appliances such as fan, television, refrigerator e.t.c that were within its maximum capacity of 1700W.

Keywords: SG3525, IRF3205, optocoupler, inductive load, capacitive load, MOSFET